1. Palatal plate maxillary major connector should end onPosterior palatal seal areaJunction of hard and soft palateSoft palateAlways on hard palateQuestion 1 of 20 2. Bennett movement is recorded in?Sagittal movementLateral movementVertical movementFrontal movementQuestion 2 of 20 3. Which of the following is a shrink free ceramicCerestoreEmaxDicorDicor MGCQuestion 3 of 20 4. To identify mobile implants at the abutment connection using a reverse- torque test, the force should not exceed:25Ncm10 Ncm20Ncm5 NcmQuestion 4 of 20 5. A disadvantage of long span flexible major connector in a partial denture isDecreased stability of prosthesiscannot be relinedexcessive forces on residual ridge and periodontal ligament of abutment teethExcessive forces on residual ridge onlyQuestion 5 of 20 6. Which sounds help determine the labiolingual position of the anterior teethThe b, p amd m soundsFricatives or labiodental sounds(such as f, v or ph)Linguodental sounds(such as this ,that or those)Linguoalveolus sounds or sibilants(such as s, z , sh and ch)Question 6 of 20 7. Design of maxillary major connector depends onIndirect retentionForce distributionOral comfortDirect retentionQuestion 7 of 20 8. Modified "T" clasp is basically aT clasp with retentive fingerT clasp with no retentive fingerT clasp with no nonretentive fingerT clasp with nonretentive fingerQuestion 8 of 20 9. The property involved when a denture base clasp is adjusted isElastic limitPercentage elongationHardnessProportional limitQuestion 9 of 20 10. what is the function of guiding plane in a cast partial denturemultiple paths of insertion and removalcreation of food trapssingle path of insertion and removalretention against dislodgementQuestion 10 of 20 11. After the healing period, the best noninvasive method to verify secondary implant stability and osseointegration of the implant isimplant percussionresonance frequency analysisreverse torqueperiotestQuestion 11 of 20 12. Which of the following are the most appropriate for use as overdenture abutments?Second premolars.Central incisors.Canines.First premolarsQuestion 12 of 20 13. Soldering flux is composed of all of the following EXCEPT one. Which one is the EXCEPTION?alumsodium pyroboratesilicaboraxQuestion 13 of 20 14. D1 bone found mainly at?. Posterior maxillaPosterior mandible. Anterior maxillaAnterior mandibleQuestion 14 of 20 15. The occlusion rehabilitation in an implant patient differs from natural teeth occlusion, even in a normal occlusion patient, because:implant- bone relationimplant angulationlimited crown height spacebone ResorptionQuestion 15 of 20 16. The path of insertion of RPD is guided byAll undercut areasGuiding planesall of the aboveRetentive areasQuestion 16 of 20 17. A dental laboratory has fabricated a removable partial denture framework. The framework fits the master cast well but when tried in the mouth a stable fit cannot be achieved. The most likely cause isimproper casting temperature.distortion in the final impression.improper major connector design.shrinkage of the alloy during casting.Question 17 of 20 18. The highest force exerted during occlusion occurs when a dental implant opposes:dental implantremovable denturenatural teethfixed prosthesisQuestion 18 of 20 19. A patient with class III mobility of upper and lower teeth is suggested immediate complete dentures. When both maxillary and mandibular immediate complete dentures are proposed then what is the recommended protocolConstruct mandibular firstWait for complete healing of tissuesMake the maxillary first followed by the mandibularThey should be constructed togetherQuestion 19 of 20 20. Nesbit prosthesis isSilicon based nasal prosthesisRemovable prosthesisEar prosthesisGuidance device for hemimandibulectomy patientQuestion 20 of 20 Loading...